Pressure Calibrators


New 2019
HPC50 series Digital Pressure Calibrators
  • Intrinsic safety
  • Any combination of external pressure and temperature modules can be added to the HPC50 (APMi module for pressure, and the ATMi module for temperature)
  • Pressure (one or two internal modules, ext modules) measurement range -0.1...100 MPa, accuracy up to ±0,025%RDG
  • Measurement of mA and V, accuracy up to ±0,015%RDG
  • Generation of mA, accuracy up to ±0,015%RDG
  • Calibration systems in rigid cases with pumps
Series PG9600 Pneumatic Piston Gauges
  • Generation of absolute, gauge pressure or differential gas pressure (under static pressure) in the range of 11 kPa ... 10 MPa, accuracy up to ±0.0011% RDG
  • Automated operation and documenting under the control of Compass for Pressure calibration software
Series PG7000 Piston Gauges
  • Generation of absolute, gauge pressure and differential gas pressure (under static pressure) in the range of 5 kPa ... 500 MPa, accuracy up to ±0,0012% RDG
  • Automated operation and documenting under the control of Compass for Pressure calibration software
PKII, RK Pneumatic Deadweight Testers
  • Generation of gauge pressure in the range of 1...2000 kPa, accuracy up to ±0.015% RDG
  • Pressure source: instrument air
T, DM Hydraulic Deadweight Testers
  • Generation of gauge pressure in the range of 0.1...100 MPa, accuracy up to ±0,015% RDG
  • Pressure source: hand pump with 1200 cm³ reservoir generating up to 100 MPa
HPC40 series Digital Pressure Calibrators
  • Pressure (one or two internal modules, ext modules) measurement range -0.1...100 MPa, accuracy up to ±0,025%RDG
  • Measurement of mA and V, accuracy up to ±0,015%RDG
  • Generation of mA, accuracy up to ±0,015%RDG
  • Calibration systems in rigid cases with pumps
Crystal nVision Intrinsically Safe Digital Pressure Calibrator-Recorder
  • 0ExiaIIBT3/T4Ga X intrinsically safe calibrators
  • Pressure/differential pressure measurement and recording -0.1...100 MPa, accuracy up to ±0,025%RDG
  • Measurement and recording of mA, V and resistance, accuracy up to ±0,015%RDG
  • CPF ‑ unique quick connection fitting system finger-tight up to 70 MPa
  • Automated calibration under the control of JofraCal calibration software (Russian version available)
Crystal series 30 Intrinsically Safe Digital Pressure Calibrators
  • 1ExiaIICT4Gb X intrinsically safe calibrators
  • Pressure (one or two sensors) measurement range -0.1...30 MPa, accuracy up to ±0,05%RDG
  • Measurement of mA signal, accuracy up to ±0,025%RDG
Crystal XP2i Intrinsically safe digital pressure gauges
  • Intrinsically safe 0ExiaIICT4/T3Ga X
  • Pressure measurement range -0,1...100 MPa, accuracies ±0,1% RDG, optional ±0,02% FS or ±0,05% FS
  • CPF: unique quick connection fitting system - finger-tight up to 70 MPa
Crystal XP2i-DP intrinsically safe differential digital pressure gauges
  • Intrinsically safe 0ExiaIICT4/T3Ga X
  • Differential pressure measurement range ±100/700 kPa, continuous deep vacuum measurements, accuracy down to ±0,1% RDG, max safe pressure 700 kPa
Crystal m1 pressure gauge
  • Pressure measurement range -0,1...70 MPa, accuracy down to ±0,2% RDG
  • CPF: unique quick connection fitting system - finger-tight up to 70 MPa
6270A Pressure Controller / Calibrator
  • Calibrate a wide range of pressure gauges and sensors from very low pressure to 20 MPa with this reliable, easy-to-maintain pressure calibrator
  • Unsurpassed rangeability in one pressure controller / calibrator: install up to five measurement modules with uncertainty as good as 0.01% of reading from 30% to 100% of the modules' span
  • Fully automated operation and documenting under the control of Compass for Pressure calibration software
Industrial Pressure Calibrator 2271А
  • Calibration of a wide range of pressure gauges and sensors from very low pressure to 20 MPa with this reliable, easy-to-maintain pressure calibrator
  • Unsurpassed rangeability in one pressure controller / calibrator: install up to two measurement modules with uncertainty as good as 0.02%FS
  • DUT analog output and HART signal reading, loop power supply
  • Automatic calibration of pressure transducers, internal memory for saving results
  • Fully automated operation and documenting under control of Compass for Pressure calibration software
PPC4 Pneumatic Pressure Controllers
  • Measurement, setting and maintenance of absolute and gauge gas pressure in the range of up to 10 MPa, accuracy up to ±0.008% RDG
  • Fully automated operation and documenting under the control of Compass for Pressure calibration software
PPCH Hydraulic Pressure Controllers
  • Measurement, automatic setting and maintenance of absolute and gauge pressure in the range of up to 200 MPa, accuracy up to ±0.013% RDG
  • Fully automated operation and documenting under the control of Compass for Pressure calibration software
RPM4 Precision Pressure Calibrator
  • Measurement of absolute, gauge and differential pressure in the range of up to 280 MPa, accuracy up to ±0.008% RDG
  • Possibility of integration in a system with PPC4, PPCH-G, PPCH controllers
  • Documenting capacity under the control of Compass for Pressure calibration software
RPM4-E-DWT-H Hydraulic Digital Pressure Calibrators
  • Generation of gauge pressure in the range of up to 200 MPa, accuracy up to ±0.02% RDG
  • Built-in screw hand pump
  • Documenting capacity under the control of Compass for Pressure calibration software
Manual Pneumatic Pressure Controller 3990
  • Pressure control in the range of up to 20 MPa
  • Possibility of differential pressure setting under static pressure
GB-H-152 Manual Pneumatic Pressure Controller with Booster
  • Maximum output pressure of up to 120 MPa, input pressure over 4.8 MPa required
  • Nominal gas booster piston ratio of 152
GPC1 Precision Pneumatic High-Pressure Controller
  • Maximum output pressure of up to 110 MPa
  • Air supply pressure of 300...850 kPa is required for fine adjustment
OPG1 Precision Hydraulic Controller
  • Maximum output pressure of up to 200 MPa
  • Hydraulic pump generates output pressure 400 times higher than that in pneumatic actuator
  • Air supply pressure of 550...850 kPa is required for fine adjustment
Hand Pumps
  • pneumatic up to 21 MPa
  • hydraulic up to 200 MPa
  • fine adjustment, safety valves
  • cases, hoses, fittings, adapters, dirt traps
Manual Hydraulic Booster
  • Pressure range of up to 500 MPa, boost ratio of 5:1
  • Recommended to use with MPG2-H or OPG1